Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 12.6/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL |
HSC-100-3.3 |
HSC-100-5 |
HSC-100-12 |
HSC-100-15 |
HSC-100-24 |
HSC-100-48 |
|
OUTPUT |
DC Voltage |
3.3V |
5V |
12V |
15V |
24V |
48V |
Rated Current |
20A |
16A |
8.5A |
7A |
4.5A |
2.3A |
|
Current Range |
0~20A |
0~16A |
0-8.5A |
0-7A |
0-4.5A |
0-2.3A |
|
Voltage Tolerance |
±3.0% |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|
Line Regulation |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Load Stability |
±2.5% |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Rated Power |
66W |
80W |
102W |
105W |
108W |
110.4W |
|
Ripple & Noise |
80mVp-p |
80mVp-p |
120mVp-p |
120mVp-p |
120mVp-p |
200mVp-p |
|
DC Adjustment Range |
3.2V~3.5V |
4.75~5.5V |
11.4 ~ 13.2V |
14.25~ 16.5V |
22.8-26.4V |
45.6 ~ 52.8V |
|
Setup, Rise Time |
500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load |
||||||
Hold Time |
100ms/230VAC 18ms/115VAC at full load |
||||||
INPUT |
Voltage Range |
88 ~ 264VAC125 ~ 373VDC (Withstand 300VAC surge for 5sec,Without damage) |
|||||
Frequency |
47~63Hz |
||||||
Efficiency |
74% |
77% |
81% |
82% |
84% |
84% |
|
AC Current |
2.5A/115VAC 1.5A/230VAC |
||||||
Inrush Current |
Cold start 40A/230VAC |
||||||
Leakage Current |
<2mA / 240VAC |
||||||
PROTECTION |
Over Load |
110 ~ 150% |
|||||
Protection: Hiccup mode, recovers automatically after fault condition is removed |
|||||||
Over voltage |
3.8~4.45V |
5.75~6.75V |
13.8~16.2V |
17.25~20.25V |
27.6~32.4V |
55.2~64.8V |
|
Protection: Hiccup mode, recovers automatically after fault condition is removed |
|||||||
ENVIRONMENT |
Working Temp., Humidity |
-25~+70ºC, 20 ~ 90% RH |
|||||
Storage Temp., Humidity |
-40 ~ +85ºC , 10 ~ 95% RH |
||||||
Vibration |
10 ~ 500Hz, 5G 10min./ 1cycle, period for 60min, each along X, Y, Z axes |
||||||
SAFETY |
Withstand Voltage |
I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC |
|||||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC |
||||||
STANDARD |
Safety Standard |
Design refer to UL60950-1,TUV EN60950-1 |
|||||
EMC Standard |
Design refer to EN55022 CLASS B,EN61000-3-2,-3;EN61000-4-2,3,4,5,6,8,11;ENV50204,EN61000-6-2(EN50082-2) |
||||||
OTHERS |
Weight |
0.6Kg |
|||||
Packing |
30pcs/18.5Kg/0.99CUFT |
||||||
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Tolerance: includes set up tolerance, line regulation and load regulation 3.Line Regulation is measured from low line to high line at rate load. 4.Load Stability is measured from 0% to 100% rated load. 5. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 6.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at cold first start, turning on-off the power supply very quickly may lead to increase of the set up time. |