• 24kv Indoor Current Transformer Current Measuring Intrument Current Metering Instrument

24kv Indoor Current Transformer Current Measuring Intrument Current Metering Instrument

Application: Instrument, Measurement and Protection
Type: Current Transformer
Phase: Single
Operation Condition: Indoor
Usage: Protection, Measurement, Measurement and Protection
Winding Form: Multilayer Honeycomb Type
Samples:
US$ 115/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company
Gold Member Since 2004

Suppliers with verified business licenses

Zhejiang, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 1 Self-brands, check the Audit Report for more information
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
to see all verified strength labels (28)

Basic Info.

Model NO.
LZZBJ9-24
Insulating Medium
Epoxy Resin
Installation
Strut Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Type of Current Transformer
Indoor Use, Epoxy Resin, Sealed Structure
Rated Voltage
24kv
Applicable Standard
IEC60044-1, IEC61869-2
Combined Accuracy Classes
0.2/10p10, 0.5/10p10
Transport Package
1PCS/CTN
Specification
20/5A~500/5A
Trademark
DHECN
Origin
China
HS Code
8504311000
Production Capacity
5000PCS/Month

Product Description

LZZB9-24/180b/2(4) Type Current Transformer
LZZB9-24/180b/2(4) Type Current Transformer
Applications
LZZB9-24/180b/2(4) Current transformer is suitable for power measurement, current monitoring and relay protection in power system with rater frequency 50Hz or 60Hz and rater voltage 10kV.
Applicable Standard: IEC60044-1, GB 1208.
Type Designation
   
Operation Conditions
Installation area: Indoor.
Ambient temperature: Max. temperature 40ºC;Min. temperature -5ºC;Daily average temperature can't exceed 30ºC.
Air conditions: No heavy pollution in air.
Technical Parameter

Technical parameters of LZZB9-24/180b/2 current transformer
Model Rated primary current
(A)
Combined accuracy classes Rated output
(VA)
Rated short-time thermo current
(kA/s)
Rated dynamic stability current
(kA/s)
LZZB9-24/180b/2 20 0.2/0.2
0.2/0.5
0.2/10P10
0.5/10P10
0.2/10P15
0.5/10P15
10/10
10/10
10/15
10/15
10/10
10/10
3 7.5
30 4.5 11.25
40 6 15
50 7.5 18.75
75 11.25 28.125
100 15 37.5
150 22.5 56.25
200 31.5 80
300 45 112.5
400
500
600 0.2/0.2
0.2/0.5
0.2/10P10
0.5/10P10
0.2/10P15
0.5/10P15
15/15
15/20
10/20
15/20
10/15
15/15
63 130
800
1000 80 160
1200
1250

Rated secondary current: 5A or 1A.
Insulation level: 24/65/125kV.

Technical parameters of LZZB9-24/180b/4 current transformer
Model Rated primary current
(A)
Combined accuracy classes Rated output
(VA)
Rated short-time thermo current
(kA/s)
Rated dynamic stability current
(kA/s)
LZZB9-24/180b/4 20 0.2/0.2/0.2
0.2/0.5/0.5
0.2/10P10/10P10
0.5/10P10/10P10
0.2/10P15/10P15
0.5/10P15/10P15
10/10/10
10/10/10
10/15/15
10/15/15
10/10/15
10/10/15
3 7.5
30 4.5 11.25
40 6 15
50 7.5 18.75
75 11.25 28.125
100 15 37.5
150 22.5 56.25
200 31.5 80
300 45 112.5
400
500
600 0.2/0.2/0.2
0.2/0.5/0.5
0.2/10P10/10P10
0.5/10P10/10P10
0.2/10P15/10P15
0.5/10P15/10P15
15/15/15
15/20/20
10/20/20
15/20/20
10/15/15
15/15/15
63 130
800
1000 80 160
1200
1250
 
Structure and Feature
Current transformer have the whole-sealed structure with epoxty resin as its main insulation. Its core adopts the crystallitic alloy or excellent silicon steel sheets to enwind becoming annular, then secondary leads are enwinded on it evenly. Primary conducts are winded by insulation belt to avoid short circuit between conducts. There are earth bolts and holes suitable for mounting on the bottom of the product suitable the mounting


24kv Indoor Current Transformer Current Measuring Intrument Current Metering Instrument

24kv Indoor Current Transformer Current Measuring Intrument Current Metering Instrument
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now