Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 6.5/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL |
HDR-45-5 |
HDR-45-12 |
HDR-45-15 |
HDR-45-24 |
|
OUTPUT |
DC Voltage |
5V |
12V |
15V |
24V |
Voltage Tolerance |
±2% |
±1% |
±1% |
±1% |
|
Rated Current |
5A |
3.5A |
2.8A |
2A |
|
Current Range |
0-5A |
0-3.5A |
0-2.8A |
0-2A |
|
Rated Power |
25W |
42W |
42W |
48W |
|
Ripple & Noise |
100mVp-p |
200mVp-p |
240mVp-p |
480mVp-p |
|
DC Adjustment Range |
4.75-5.5V |
10.8-13.2V |
13.5-16.5V |
21.6-26.4V |
|
Setup, Rise, Hold Time |
800ms,60ms,100ms/230VAC at full load |
||||
INPUT |
Voltage Range |
85~264 VAC47~63 Hz;120~370VDC |
|||
AC Current |
1.5 A/115 V 0.75A/ 230 V |
||||
Efficiency |
72% |
77% |
77% |
80% |
|
Inrush Current |
Cold start 28A/115V 56A/230V |
||||
Leakage Current |
<1mA/240VAC |
||||
PROTECTION |
Over Load |
105%~150% |
|||
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
|||||
Over Voltage |
115%~135% |
||||
Protection type: Shut down o/p voltage, re-power on to recover |
|||||
Over Temp |
Tj 135 typically (U1) Detect on heat sink of power transistor,shut down o/p voltage, recovers automatically after temperature goes down |
||||
ENVIRONMENT |
Working Temp., Humidity |
-10ºC~+50ºC;20%~90 %RH |
|||
Storage Temp., Humidity |
-20ºC~+85ºC;10%~95 %RH |
||||
Vibration |
10~500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
||||
SAFETY |
Withstand Voltage |
I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC |
|||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC |
||||
STANDARD |
Safety Standard |
Design refer to UL508,TUV EN60950-1 |
|||
EMC Standard |
Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2 |
||||
OTHERS |
Weight |
0.31Kg |
|||
Packing |
48pcs/16.1Kg/1.3CUFT |
||||
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |