Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 15/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
MODEL:HDR-120 Single Output Industrial DIN Rail Power Supply
|
||||||
|
||||||
MODEL |
HDR-120-12 |
HDR-120-24 |
HDR-120-48 |
|||
OUTPUT |
DC Voltage |
12V |
24V |
48V |
||
Voltage Tolerance |
±2% |
±1% |
±1% |
|||
Rated Current |
10A |
5A |
2.5A |
|||
Current Range |
0-10A |
0-5A |
0-2.5A |
|||
Rated Power |
120W |
120W |
120W |
|||
Ripple & Noise |
80mVp-p |
80mVp-p |
100mVp-p |
|||
DC Adjustment Range |
12-14V |
24-28V |
48-53V |
|||
Setup, Rise Time |
500ms,70ms/230VAC at full load500ms,70ms/115VAC at full load |
|||||
Hold Time |
36ms/230VAC32ms/115VAC at full load |
|||||
INPUT |
Voltage Range |
88~132 VAC/176~264VAC47~63 Hz;selected by 248~370VDC |
||||
AC Current |
2.6 A/115 V 1.6A/ 230 V |
|||||
Efficiency |
80% |
84% |
85% |
|||
Inrush Current |
Cold start 20A/115V 40A/230V |
|||||
Leakage Current |
<3.5mA/240VAC |
|||||
PROTECTION |
Over Load |
105%~150% |
||||
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
||||||
Over Voltage |
120%~135% |
|||||
Protection type: Shut down o/p voltage, re-power on to recover |
||||||
Over Temp |
85ºC±5ºC(TSW1) |
90ºC±5ºC(TSW1) |
90ºC±5ºC(TSW1) |
|||
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down |
||||||
ENVIRONMENT |
Working Temp., Humidity |
-10ºC~+60ºC;20%~90 %RH |
||||
Storage Temp., Humidity |
-20ºC~+85ºC;10%~95 %RH |
|||||
Vibration |
10~500Hz,2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
|||||
SAFETY |
Withstand Voltage |
I/P-O/P:3KVAC I/P-O/P:1.5KVAC O/P-FG: 0.5KVAC |
||||
Isolation Resistance |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC |
|||||
STANDARD |
Safety Standard |
Design refer to UL508,UL60950-1,TUV EN60950-1 |
||||
EMC Standard |
Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2) |
|||||
OTHERS |
Weight |
0.79Kg |
||||
Packing |
20pcs/16.5Kg/1.1CUFT |
|||||
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |