Home » Product List » PFC&Charger Series » 75W Single Output Switching Power Supply With PFC Function (HSP-75)
Product Details
75W Single Output Switching Power Supply With PFC Function (HSP-75)
| Model NO.: | HSP-75 |
|---|---|
| Standard: | ISO9001, CCC, CB, CE, ROHS |
| Productivity: | 15000pcs/month |
| Unit Price: | Negotiable |
| Shipment Terms: | Sea Freight or Air Freight |
| Payment Terms: | T/T |
| Price Valid Time: | From Aug 31,2011 To Dec 31,2014 |
| HS Code: | 85044019 |
| Trademark: | DHECN |
| Output Type: | Single |
| Output Power: | 51 - 100W |
| Input Voltage: | Full Range |
| Starting Mode: | Separate-excited Switching Power Supply |
| Connection Mode: | Parallel Switching Power Supply |
| Export Markets: | North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe |
Features:
Universal AC input / Full range
Built-in active PFC function, PF>0.93
100% full load burn-in test
Protections: Short circuit / Over load / Over voltage
Built-in constant current limiting circuit
LED indicator for power on
Fixed switching frequency at PFC: 67KHz, PWM: 134KHz
3 years warranty
Dimension: 179*99*33mm (L*W*H)
Specification:
1) INPUT
Voltage Range: 85-264VAC, 120-370VDC; 47-63Hz
Power Factor: PF>0.95/230VAC PF>0.96/115VAC at full load
AC Current: 1.3A/115VAC 0.7A/230VAC
Inrush Current: Cold start 40A/230VAC
Leakage Current: <2mA/240VAC
2) PROTECTION
Over Load: 105%-150%; Constant current limiting, recovers automatically after fault condition is removed.
Over Voltage: 115%-135%; Shut down o/p voltage, re-power on to recover.
Remote control(option): CN3: 4-10VDC POWER OFF, <0-0.8VDC POWER ON
3) ENVIRONMENT
Working Temp. & Humidity: -10ºC~+60ºC; 20%~90% RH.
Storage Temp. & Humidity: -20ºC~+85ºC; 10%~95% RH.
Vibration: 10~500Hz, 2G 10min./1 cycle, period for 60min, each along X, Y, Z axes.
4) SAFETY STANDARDS
Withstand Voltage; I/P-O/P: 3KVAC; I/P-FG: 1.5KVAC; O/P-FG: 0.5KVAC
Isolation Resistance: I/P-O/P, I/P-FG, O/P-FG: 100MΩ/500VDC
Safety Standards: Design refer to UL1950, TUV, EN60950
EMC Standards: Design refer to EN55022, EN61000-3-2,-3, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024
5) Type No | Output | Tol. | R&N | Effi.
HSP-75-3.3 | 3.3V, 15A | ±2% | 80mV | 68%
HSP-75-5 | 5V, 15A | ±2% | 80mV | 72%
HSP-75-7.5 | 7.5V, 10A | ±2% | 80mV | 74%
HSP-75-12 | 12V, 6.3A | ±2% | 80mV | 77%
HSP-75-13.5 | 13.5V, 5.6A | ±2% | 80mV | 78%
HSP-75-15 | 15V, 5A | ±2% | 80mV | 79%
HSP-75-24 | 24V, 3.2A | ±1% | 100mV | 80%
HSP-75-27 | 27V, 2.8A | ±1% | 100mV | 80%
HSP-75-48 | 48V, 1.6A | ±1% | 100mV | 80%
Inquiry Basket (